ELETTRA Parameters

Beam energy [GeV] 22.4
Storage ring circumference [m]259.2  
Beam height in experimental area [m]1.3  
Number of achromats12  
Length of Insertion Device (ID) straight sections [m]6(4.8 utilizabile per ID's)  
Number of straight sections of use for ID's11  
Number of bending magnet source points12  
Beam revolution frequency [MHz]1.157  
Number of circulating electron bunches1 - 432  
Time between bunches [ns]864 - 2  
Tunes: horizontal/vertical14.3/8.2  
Natural emittance [nm-rad] 79.7
Energy lost per turn without ID's [keV] 255.7533
Maximum energy lost per turn with ID's [keV] (all) 315618.5
Critical energy [keV] 3.25.5
Bending magnet field [T] 1.21.45
Geometrical emittance coupling %£ 1%  
Spurious dispersion (at the centre of IDs): horizontal (rms max/min) [cm]6/2.  
Spurious dispersion (at the centre of IDs): vertical (rms max/min) [cm]2/0.5  
Injected current [mA] 320150
Machine dominated by the Touschek effect   
Energy spread (rms) % 0.080.12
Lifetime [h] (natural)
Lifetime [h] (with 3rd harmonic cavity)
  8.5
27
32
32
Bunch length (1 σ) [mm]* 5.47
Beam dimensions (1 σ)*   
ID source point - horizontal/vertical [µm] 241/15283/16
Bending magnet source point - horizontal/vertical [µm] 139/28197/30
Beam divergence (1 σ)*   
ID source point - horizontal/vertical [µrad] 29/6.35/8.
Bending magnet source point - horizontal/vertical [µrad] 263/9370/13


*The values shown (taking into account the energy spread) are averages, obtained from a consideration of different angle and position values of the spurious dispersion and can vary by ±10%


ID parameters