Elettra-Sincrotrone Trieste S.C.p.A. website uses session cookies which are required for users to navigate appropriately and safely. Session cookies created by the Elettra-Sincrotrone Trieste S.C.p.A. website navigation do not affect users' privacy during their browsing experience on our website, as they do not entail processing their personal identification data. Session cookies are not permanently stored and indeed are cancelled when the connection to the Elettra-Sincrotrone Trieste S.C.p.A. website is terminated.
More info
OK

How to adjust PreVERT pitch ALONG the beam

ENCODER: http://082f-bcs.blcs.elettra.trieste.it/blcs/CENTRAL/SM2/EDA2_20/1ADC1?ACTION=GET

SM2--- [0] (EDA2_20) Piezo controller----[1] (1ADC1) 1 posit. range

NOTA: Encoder deve stare tra 0 e 150 V, possibilmente attorno a 75


MICROMETRO SCALA NERA dentro hutch 
Old position=25 mm (micrometro lungo la linea), Prevert pitch=248. Encoder=8 V
intermediate movements
24.6, pitch=308, -1.4V
25.8, pitch=58.4 33V
26.6, pitch=-137, 60.9V

dopo alcuni mesi il pitch va a -475
25, pitch=-200, 44.67
25.5, pitch=-150, 63.3

Now=25.5 mm, Prevert pitch=-130. Encoder=60 V

Sulla scala nera ci siamo mossi di 8 tacche (da 25 a 26.6).

OLD Micrometro prevert pitch dentro hutch (lungo in fascio): 26 mm (9/12/2009). Era: 23 mm il 8/12/2009. Da 26 a 23 il preverpitch si e' spostato di circa 600 micron verso valori piu' bassi (da oltre 400 a -186).

15/02/2016  Micrometer position: OLD  27 (scala nera) --->  NEW 25.3 (scala nera),  
                       Pitch prevert: OLD  <-480 (encoder >100 V)  --->  NEW   40 (encoder 38 V)

08/07/2016  Micrometer position: OLD 25.3 (scala nera)---> NEW 27 (scala nera)                   
                       Pitch prevert: OLD 310 (encoder -1.4V) ---> NEW -113 (encoder 57 V)
 

Last Updated on Friday, 08 July 2016 11:49