Source
source: 2 Apple II type undulators 10 cm period,
with phase modulation electromagnet
polarisation: linear horizontal, linear vertical, elliptical (circular as special case)
energy range: 5-1000 eV
[the optimum phase for measurements requiring circular polarisation can be found here]

Monochromator
grating   energy range   resolving power   maximum flux
VLS 400   200-1000 eV   4000 @ 400eV   more than 1·1012 photon/sec   [250-600eV]*
VLS 200   50-300eV   4000 @ 200eV   more than 1·1013 photon/sec  [100-200eV]*
SG10   5-20eV   1000 @ 20eV  
(*) at 200mA ring current, 2.0 GeV; 10 μm exit slit width

Photon beamspot
end-station beam spot
(hor. x vert.)
  angle of incidence
on sample
SPELEEM (first branchline) 25μm x 3μm   16° along vert.
second branchline 7μm x 3μm   normal to the beam.