Device Server |
| |
|||
( Span Frequency, in MHz ) |
|||
( Sets or retrieves the central frequency. This is listed in the base IVI Spec functions. ) |
|||
( Sets or retrieves the central frequency. This is listed in the base IVI Spec functions. ) |
|||
( The point on the y-axis corresponding to the value of the marker IVI Spec compliance: IviSpecAnMarker Extension Group. ) |
|||
( This function periodically polls the device and reads its status, signaling malfunctioning. ) |
|||
( Specifies the input attenuation (in positive dB). IVI Spec base attribute. ) |
|||
( Specifies the detection method used to capture and process the signal. IVI SpecAn base attribute. ) |
|||
( Sets the start frequency. IVI SpecAn base functions. ) |
|||
( Sets the stop frequency. IVI SpecAn base functions. ) |
|||
( Specifies the frequency offset for all frequency readouts such as center frequency, except that it does not affect marker count. IVI SpecAn base functions. ) |
|||
( Sets the amplitude of the reference level for the y axis. This is used as reference for amplitude measurements. This is typically set to a value slightly higher than the highest expected signal level. The units are determined by the amplitude units attribute. IVI SpecAn base attributes. ) |
|||
( The query stops any new commands from being processed until the current process is complete. IEEE common commands. ) |
|||
( Sets the resolution bandwidth from 1kHz to 5MHz. IVI SpecAn base attribute. ) |
|||
( Specifies the minimum signal level for thee analyzer's internal peak identification routine to recognize a signal as a peak. This applies to all traces and all windows. Manual 5-22 ) |
|||
( Specifies the minimum signal excursion above the threshold for the internal peak identification routine to recognize a signal as a peak . The excursion is the delta power between the noise level and the signal peak. Manual: 5-21. ) |
|||
( Sets/reads synchrotron frequency. ) |
|||
( Window around fs in which we look for peaks. ) |
|||
( Sets or reads the number of bunches. Its default value is read from the corresponding class property. ) |
|||
( Sets and reads the number of sweeps. See the related class property for details. This instrument supports only single and continuous sweep. IVI SpecAn base attribute. ) |
|||
( Synchrotron fundamental frequency. This is also a class property. ) |
|||
| |
|||
( Sets the start and stop frequencies. Center frequency will be in the middle. ) |
|||
( Vector containing the Y values corresponding to the 401 points of the spectrum. IVI SpecAn base function. ) |
|||
( Y values corresponding to the 401 points in X axis of the spectrum analyzer. IVI SpecAn base function. ) |
|||
( Retrieves the signal peaks. ) |
|||