Elettra-Sincrotrone Trieste S.C.p.A. website uses session cookies which are required for users to navigate appropriately and safely. Session cookies created by the Elettra-Sincrotrone Trieste S.C.p.A. website navigation do not affect users' privacy during their browsing experience on our website, as they do not entail processing their personal identification data. Session cookies are not permanently stored and indeed are cancelled when the connection to the Elettra-Sincrotrone Trieste S.C.p.A. website is terminated.
More info
OK

Beamline Description


The interconnected set of UHV chambers includes state-of-the-art surface preparation and survey (Ar ion sputtering, annealing, controlled evaporation, LEED/Auger characterization), atomic resolution scanning tunneling microscope (STM), and two spectroscopic end stations connected to two distinct beamlines.
Photons with chosen polarization are emitted by two non-collinear Apple II type insertion devices. The low energy beamline (APE-LE) covers 8-120eV photon energy range dedicated to high resolution ARPES; the high energy beamline (APE-HE) covers 150-1600 eV photon energy range used for XAS, XMCD, XMLD, XPS. Both end stations are equipped with cryostats (minimum sample temperature during the measurements is 16 K (30 K) at APE-LE (APE-HE)).

The ARPES-dedicated low energy end station has undergone an important upgrade within the NFFA demonstrator and from November 2014 hosts VG-Scienta DA30 electron energy analyzer that operates in deflection mode and allows for detailed k-space mapping at fixed sample geometry (fixed angle). The total measured energy resolution (analyzer, temperature, photons) is ~6meV, while the angular resolution is <0.2°. Also within the NFFA demonstrator the analyzer will soon (February 2015) be complemented with two VLEED-based scattering chambers for the determination of spin direction of the photo-emitted electrons, becoming the first facility for spin-resolved ARPES at Elettra.

The high energy end station hosts complementary spectrometers allowing for soft-X-ray absorption (XAS), magnetic dichroism (XMCD, XMLD) and X-ray photoelectron spectroscopy (XPS). Samples can be loaded into the APE system via two differentially pumped load-locks and then transferred in UHV to any of the preparation chambers, to STM and to both end stations. APE also allows the integration of users' specialized sample growth chambers, which may be connected to the main sample distribution chamber and have full access to the off-beam and on-beam facilities.

APE beamlines and APE laboratory are illustrated in the figures below. For detailed description, please see: Rev. Sci. Instrum. 80, 043105 (2009); doi:10.1063/1.3119364.